Infusion syringe Pump

Infusion syringe Pump
Product Detailed
Infusion Pump syringe pump We can supply kinds of syringe pumps, precise injects, good quality, competative price.

Micro Infusion Pump,syringe pump

We can supply kinds of syringe pumps, precise injects, good quality, competative price.

l         Flow rate :   0.01-300.0ml/h (10ml syringe)

0.01-399.9ml/h (20ml syringe)

0.01-600.0ml/h (30ml syringe)

0.01-1200ml/h (50ml syringe)

l         Purge rate:   300.0ml/h (10ml syringe)

            399.9ml/h (20ml syringe)

    600.0ml/h (30ml syringe)

1200ml/h (50ml syringe)

l         Volume To Be Infused (VTBI): 0.1-9999ml

l         Bolus volume: 0.1-60.0ml

l         Bolus rate:   0.01-300.0ml/h (10ml syringe)

0.01-399.9ml/h (20ml syringe)

0.01-600.0ml/h (30ml syringe)

0.01-1200ml/h (50ml syringe)

l         Drug library:  174 kinds of drugs in the drug library

l         Precision:   ≤±2%(machine precision<±1%)

l         Occlusion pressure: 3-level is available

                    L: 300±100 mmHg (40.7±13.3 KPa)

M: 500±100 mmHg (66.7±13.3 KPa)

H: 800±200 mmHg (106.7±26.7 KPa)

l         Alarms: nearly empty, empty, bolus finished, VTBI finished, dose rate exceed the recommend range, flow rate exceed the range, syringe dislocated, syringe disengaged, malfunction, start remind (the pump isnt started within 2 min. while power on), OCCLUSION, repeat alarm (the alarm isnt disable within 2 min. after silenced), pressure sensor failure, capacity of battery nearly empty, capacity of battery exhausted, main cable unconnected, AC power failure.

l        Indication: VTBI, total volume infused, Remain time of infusion, drug name, dose, patient weight, solution volume, drug volume, concentration, event log, syringe brand, battery capacity indicate, local time, flow rate, system pressure etc.

l         Power: AC220V±22V,50HZ±1HZ

          Internal battery: DC12V, can work for approx. 3.8h at 5ml/h

          (new battery, recharged for 16 hours or more with ambient temperature 25 degree.)                                                                                                                                                        

l         Power consumption: 12VA

l         Operating conditionsa) ambient temperature+5+40

b)relative humidity   20%90%

l         Transport and storage conditions: a) ambient temperature:-40∼55

b)relative humidity:≤95%

l         Dimensions :307(W)×135(H)×128(D)mm

l         Net Weight: 2.2kg;

l         Syringe: As many as 13 kinds of syringe brands are available, see Table 1 (recommend syringe brands). And when necessary, can modify the pump for special syringe demand.